HPLC Column, RP C4 Butyl, 10um, 4.6mm ID x 150mm Length, 100A. Cogent Brand. 1 EA.
Additional Information:
Cogent RP C4 Butyl is a reversed-phase HPLC stationary phase manufactured using high-purity silica with traditional butyl (C4) ligand bonding and complete double endcapping. Classified as USP L26, this stationary phase provides moderate hydrophobic retention for compounds that may be excessively retained on more hydrophobic phases such as C8 or C18 columns. The C4 chemistry is an excellent choice for hydrophobic and neutral analytes when shorter retention times and efficient separations are desired.
68004-15P is a 150 mm x 4.6 mm ID analytical HPLC column packed with 10 µm RP C4 Butyl particles with a 100 Å pore size. The 150 mm column length provides increased resolving power and peak capacity compared to shorter columns, making it well suited for method optimization, impurity investigations, and separations that benefit from enhanced chromatographic resolution. The 10 µm particle size supports higher flow rates while maintaining lower operating backpressure, and the 4.6 mm ID format is the industry standard for conventional HPLC systems, typically operating at approximately 1.0–2.0 mL/min.
This USP L26 column is particularly useful for hydrophobic and neutral compounds requiring less retention than a C8 stationary phase. The combination of fully endcapped C4 chemistry, high-purity silica, and larger particle technology delivers robust chromatographic performance for analytical methods, scale-up studies, and preparative method development.
Key Benefits
RP C4 Butyl stationary phase
USP L26 classification
Fully double endcapped chemistry
Traditional butyl (C4) bonded phase
High-purity silica support
10 µm particles for lower backpressure
Suitable for higher flow rates
Less retention than C8 columns
Enhanced resolution from 150 mm column length
Useful for method development and scale-up studies
Typical Applications
Reversed-phase HPLC
USP L26 methods
Hydrophobic compound analysis
Neutral compound analysis
Method development
Impurity investigations
Preparative method scouting
Scale-up studies
Quality control testing
Specifications
Product Type: HPLC Column
Stationary Phase: RP C4 Butyl
USP Classification: L26
Chromatography Mode: Reversed Phase
Bonded Phase: Butyl (C4)
Endcapping: Fully Double Endcapped
Particle Size: 10 µm
Pore Size: 100 Å
Column Dimensions: 4.6 mm ID x 150 mm
Length: 150 mm
Recommended Flow Rate: 1.0–2.0 mL/min
Brand: Cogent
Important Notes
Designed for reversed-phase chromatography
Provides less retention than comparable C8 columns
Suitable for hydrophobic and neutral compounds
Larger particle size reduces operating backpressure
Longer column length improves separation of closely related compounds
Compatible with conventional HPLC systems
Alternative for many USP L26 methods